Electromagnetic compatibility (EMC)

Some of accredited test methods we provide are:

  • Harmonic emission (EN 61000-3-2)
  • Flicker emission (EN 61000-3-3)
  • Immunity to Electrical Fast Transients / Burst (EFT/B) up to 4.8 kV (EN 61000-4-4)
  • Immunity to Surge up to 6 kV (EN 61000-4-5)
  • Dips, short interruptions and voltage variation immunity (EN 61000-4-11)
  • Power frequency magnetic field immunity up to 40 A/m (EN 61000-4-8)
  • Pulse magnetic field immunity up to 1000 A/m (EN 61000-4-9)
  • Immunity to Electrostatic Discharge (ESD) up to 30 kV (EN 61000-4-2)
  • Conducted RF emission 9 kHz - 30 MHz (EN 55022, EN 55032, EN 55016-2-1 or similar)
  • Radiated RF emission 30 MHz - 2,7 GHz (EN 55022, EN 55032, EN 55016-2-3 or similar)
  • Conducted RF immunity 150 kHz - 230 MHz up to 10 V (EN 61000-4-6)
  • Immunity to radiated RF fields 80 MHz - 2,7 GHz up to 10 V/m (EN61000-4-3)
  • On site EMC testing of machines and systems

 

Other preliminirary (pre-compliance) or final (full-compliace) tests we do:

  • Radiated RF emission up to 12 GHz
  • RF emission up to 20 GHz by conducted way
  • Power disturbances 30 MHz - 1 GHz (EN 55016-2-2)
  • Immunity to radiated RF fields 80 MHz - 2,7 GHz up to ~ 30 V/m
  • Immunity to ring wave up to 6 kV (EN 61000-4-12)
  • Troubleshooting of RF disturbances in electronic circuits, intra-system EMC analyses
  • Interference testing, inter-system EMC analyses

 

EMC testing is according to various products’ standards for many prooduct groups:

  • Information technology equipment (IT)
  • Audio, video and multimedia equipment (MME)
  • Industrial, scientific and medical RF equipment
  • Electrical medical devices
  • Household appliances, electric tools and similar apparatus
  • Electrical lighting, LED, drivers, controllers and similar devices
  • Electrical meters
  • Radio and telecommunication equipment
  • Alarm systems, interphones, HBES
  • Relays, PLC and other controllers
  • Industrial equipment
  • Domestic and office equipment
  • Electrical machines or components

Radio spectrum (RF)

Some of accredited test methods we provide are:

  • Output power
  • Spectral density
  • Frequency range
  • Spurious emissions of transceiver (Tx) and receiver (Rx)
  • In-band and Out-of-band emissions (spectrum mask)

 

Other RF tests that we are also able to offer:

  • Receiver sensitivity and blocking
  • Antenna radiation pattern and optimization
  • Measurement of other RF parameters
  • On-site spectrum measurement
  • Near-field measurement

 

We perform RF testing of many types of equipment, systems and in various frequency ranges:

  • ISM bands up to 6 GHz
  • WLAN/Wi-Fi, Bluetooth, BLE, ZigBee and similar radio technologies
  • RFID/NFC at 13,56 MHz and in other bands
  • SRD devices operate in 433 MHz, 868 MHz and in other bands
  • Radio and TV broadcasting (analog/digital)
  • GSM /2G, UMTS/3G, LTE/4G
  • Wireless alarm systems, interphones, HBES
  • Wireless A/V equipment, multimedia equipment (MME)

EMF/Health

Examination or assessment of the electromagnetic field of radio devices is necessary to prove compliance with the requirements of the EU directive for radio products (RED 2014/53/EU), the Serbian Rulebook on radio equipment and other normative requirements for various markets (FCC for the USA, ICES for Canada... .). We conduct tests and evaluation:

  • Low-poweer exclusion level

  • E- and/or H- field spartial measument

  • E-field calculation

in accordance with several standards (EN 50360, EN 50364, EN 62479, EN 50566, EN 62311, EN 62369-1...).

LVD/Safety testing

  • Dielectric withstand (0.1 kV - 5 kV, up to 500 mA, 500 VA)
  • Continuity - low resistance ( up to 9.999 Ohm @ 10/25 Aac; up to 999.9 Ohm @ 0.1/0.2 Aac; 4 wires measuring system)
  • Voltage drop (up to 100 V scaled to 10 Aac)
  • Insulation resistance (up to 999 MOhm @ 250 Vdc, 500 Vdc and 1000 Vdc)
  • PE leakage current (up to 20 mA)
  • Substitute leakage current
  • Touch leakage current
  • Functional (Active Power and Apparent Power up to 3500W, 40 V, 15.9 A, cos Phi 0 - 1, 45Hz - 65Hz)
  • Discharge time (0 - 10 s @ safe levels 60 V, 120 V)
  • Ingress protection (up to IP67) and Impact code (up to IK10)
  • Temperature (up to 700 °C)
  • Clearance and Creepage distances

And other electrical safety testing methods that we carry out in our laboratory, on-site or we subcontract with our partner laboratories.

EMC automotive

Accredited testing in line with CISPR 25, ALSE method:

EN 55025:2017

EN 55025:2017/AC:2017

EN IEC 55025:2022

 

Other ESA (Electronic Automotive Subassemblies) tests:

CISPR 25, Measurement of conducted emissions from components /modules - Voltage method

ISO 7637-2, Electric transient conduction along supply only - Voltage transient emission test

ISO 7637-2, Electrical transient conduction along supply lines

ISO 10605, Test methods for electrical disturbances from electrostatic discharge (ESD)

ISO 11452-2, Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - ALSE


In line with requrements of UNECE R10 regulative and of specific standards of the vehicle manufacurers: BMW, MAN, VW, Daimler MBN...

Energy labelling

Energy consumption measurement, Energy Index and Energy Class determination for television sets (TV), monitors and displays and other aparatures for domestic and office use

 

According accredited test methods / standards:

EN 62087-3:2016

 

And in line with the EU and Serbian Energy labelling regulative.

 

 

Eco design

Measurement of maximum allowed power consumption and inspection of the other Eco-Design mandatory requirements for  computers, notebooks, vending machines, set-top boxex (STB), television sets (TV) and monitors and other office and home appliances in line with:

 

  • EU Eco-Design regulatives
  • Serbian Eco-Design regulatives
  • accrediited test methods / standards

 

EN 50564:2011 (IEC 62301)

EN IEC 62087-7:2019

EN 62623:2013

EN IEC 62623:2022

EN 62087-5:2016

 

Climatic testing

Testing of electrical and electronic equipment on envirmental stresses - testing on humidity up to 95 % RH and testing on reduces or increased temperature from - 40 ºC to +150 ºC is carried out in calibrated termo-hygro chamber according to the standards:

EN 60068-2-78

EN 60068-2-2

EN 60068-2-1

On-site testing

On-site testing is carried out for large machines, systems, equipment and facilities or at the request of the client:

  • EMC testing of machines and plants according to EN 55011, EN 50370-1, EN 50370-2 standards
  • Safety testing
  • Measurement of the shielding efficiency (electromagnetic attenuation) of Faraday cages, magnetic resonance imaging (MRI) rooms, EM test chambers...
  • Energy consumption measurement of electrical products